Bayanin Ayyuka
Yarjejeniyar MODBUS ita ce yarjejeniyar da aka fi amfani da ita a kan kayan aikin masana'antu na lantarki kuma yanzu ta zama daidaitaccen masana'antu na yau da kullun. Ta hanyar wannan yarjejeniyar, na'urorin MODBUS daban-daban (kamar PLC, DCS, HMI, na'urori daban-daban, da dai sauransu) za su iya sadarwa da juna ta hanyar cibiyar sadarwa ko hanyoyin haɗi na jerin. Duk da haka, amfani da yarjejeniyar MODBUS a kan tashar jirgin ruwa da Ethernet ya bambanta, saboda haka yana buƙatar ƙofar don kammala aikin canjin sadarwa tsakanin yarjejeniyar biyu. ADM-5850G ne kayan da aka tsara musamman don haɗa na'urorin MODBUS TCP da na'urorin MODBUS RTU / ASCII.
ADM-5850G na'urar tashar jirgin ruwa ta MODBUS ce mai aiki da yawa wanda ya haɗa MODBUS TCP, MODBUS RTU da MODBUS ASCII yarjejeniyoyi a ciki, kuma tashar jirgin ruwa ta na'urar za a iya daidaitawa ta hanyar software zuwa yanayin RS-232, RS-422 ko RS-485, mai amfani zai iya haɗa na'urorin Ethernet na MODBUS tare da na'urorin tashar jirgin ruwa na MODBUS cikin sauƙi.
Typical aikace-aikace
Kayayyakin Features
1、32 位 ARM
CPU na Cortex-m3;
2, 10 / 100M Ethernet dubawa (RJ45 dubawa);
3, Serial tashar jiragen ruwa goyon bayan 2 RS-485 / 422 dubawa, goyon bayan bandwidth kudin mai amfani da son rai saita 300 ~ 230400bps, serial tashar jiragen ruwa data bit, dakatar bit, dubawa bit duk za a iya saita, 2 serial tashar jiragen ruwa za a iya saita zuwa daban-daban bandwidth kudin;
4. Yarjejeniyar tallafi ta haɗa da: ETHERNET, ARP, IP, ICMP, IGMP, UDP, TCP, DHCP, DNS,
Modbus TCP, Modbus RTU, Modbus ASCII;
5, samar da hanyoyin aiki guda huɗu:
RTU_ Mai-girma--TCP_
Bawa
TCP_ Mafi-RTU_
Bawa32 ASCII_ Babban - TCP_
Bawa
TCP_ Babban - ASCII_
Bawa
6, Max tallafawa
Mod bus TCP babban haɗin;
7, samar da haruffa timeout lokaci ta atomatik daidaitawa aiki;
8, samar da ID taswirar aiki, aiwatar da gudanar da mai karɓar baƙi ID lambar, serial tashar jiragen ruwa 1 da serial tashar jiragen ruwa 2 suna da daban-daban ID kewayon;
9, aiki tashar jiragen ruwa, manufa IP da tashar jiragen ruwa duk za a iya saita;
10. Za a iya saita ta amfani da Web Server, Telnet, MG Configuration management software,
Software goyon bayan Windows98 / ni / NT / 2000 / XP / WIN7 / WIN8 / WIN10
da sauran tsarin aiki;
11, masana'antu grade zane, zai iya dogon lokaci kwanciyar hankali tashi a cikin m yanayi;
12, shigar da ƙarfin lantarki: DC9 ~ 48V, Max aiki halin yanzu: 200 mA, biyu ikon shigarwa;
13, aiki zazzabi: -20 ~ 75 ºC;
14, ajiya zafin jiki: -40 ~ 85ºC;15, 35mmDIN rail shigarwa hanyar;
16, girma: 103x72x27 (mm), tsawon x fadi x tsayi (mm).
Hanyar saita uwar garken ƙofar MODBUS
ADM-5850G yana da hanyoyi uku na saitawa, daidai don saitin shiga na nesa na Telnet, saitin shiga na uwar garken yanar gizo, da MG Configuration PC.
1. Saitawar shiga na WebServer